Where security and screen from view are your requirements, HiSec SR1 Louvre offers a minimum delay against forced entry thanks to its certification to A1 (SR1) from both LPS 1175 and Secured by Design. Manufactured from either 4mm or 6mm vertical and 4mm horizontal wires at mesh apertures of 76.2 x 12.7mm it helps prevent climbing due to the reduced mesh size.
The addition of our patent pending louvre panel system offers screen from view protection for secure areas and sites that prevents surveillance from outside the fence line. Louvres are installed at 4in intervals allowing you to have vision gaps in the panel or have a taller fence with louvres to a certain height. Offering you flexibility in your threat mitigation and detection. All louvres can be finished in a wide range of PPC finishes to match the existing fence line or RAL 7040 for galvanised only fencing systems manufactured from GalZal wire.
HiSec SR1 Louvre is a variation on our LPS 1175 SR1 (A1) Fencing system covered under certification 1164d/04 (HIS-SR1 #9) to issue 8, which provides the latest testing against forced entry. HiSec SR1 Loure can be used with a range of fence toppings and integrated solutions to provide a full turnkey high-security solution. Pedestrian and Vehicle gates are also available to match the fence line.

Finish
All Zaun posts/panels/gates and painted auxiliary components (for example, clamp-bars, slide bolts etc.) benefit from a protective zinc layer and electrostatically applied polyester powder coating to BS1722 p16. Care is taken with pre-treatment to ensure sound adhesion between the zinc and paint layers. In a UK C1 environment, as defined in ISO 12944 p2, this should provide a useful life expectancy of the fence of at least 15-20 years. Life expectancy in all environments can be extended by maintaining the fencing with regular washing. Useful life will be reduced if the fencing is damaged. Any coating damage should be repaired to minimise the effect on useful life.
Enhanced painting systems such as marine coatings are also available for improved life expectancy in C2-C5M environments. For a complete list of colours.
Posts & Fixings
The HiSec SR1 Louvre perimeter security fencing system features a post and clamp bar configuration, providing a simple and easy installation method. Supplied with stainless steel through bolts, washers and nuts and installed using either power or hand tools.
Louvre panels are fitted to the rear of the panel via our patent pending fixing system.


Variations
Posts are available in different lengths to accommodate panel heights and ground conditions. Additional variations are also available: Wall fixing, cranked posts or base plated, Cranked, V Shape or Top Hat extensions for barbed or razor wire, Extended posts for CCTV, electric fencing, lighting or physical security devices.
Applications
- LPS1175 approved to Security Rating A1 (SR1) and entered into the BRE RED book
- Conforms to BS1722: Part 14
- Secured By Design approved
- Provides screen from view protection against surveillance
- The close mesh pattern offers minimum climbing aids
- Available either bolt down, in-ground or with on wall post options
- Available in 4mm and 6mm vertical wire options
- Wide range of PPC colour available
To download our HiSec SR2 datasheet, please click on the link below:
To download our standard colour list, please click on the link below;
To download our brochures, please click on the link below;
| Height | 2007, 2438, 2997mm (Note: Additional heights available upon request) |
| Panel Width | 2518mm |
| Mesh Size | 76.2 x 12.7mm |
| Wire Diameter | 1no. 4 or 6mm Vertical 1no. 4mm Horizontal |
| Top Edge Projection | Minimal Projections |
| Post Size | Dependant on fencing height |
| Clamp Bar Size | 40 x 5mm |
| Post Centres | 2440mm |
| Fixing Centres | 330mm |
| Fixings | Stainless Steel Through Bolts, Nuts and Washers |
Note: Zaun manufactures 358 from cut to length line wires; the panels are not cropped. They are supplied as standard with short protruding wires on top and bottom. If flush panels are required, this should be requested at the time of enquiry.